Search results for "dental implant"
$65.00 - $70.00
$40.00 - $125.00
GBR Master (Complete Set)
Comprehensive GBR master kit that combines bone screw, auto tack, and tenting system Kit Includes: Automatic bone tac gun Short (3.5mm) & Long (4.5mm) titanium bone tacs (21 Short and Long) Bone screw (90 in different sizes, Please see chart) Tenting screw (12 in different sizes, Please see chart) Mallet Bone carrier Lingual bone tac holder Bone tac holder Handle and Handpiece screw holder Autoclavable Case Bone tac remover (BT-RM) Click here for Detailed Product Component list. How to use video Automatic bone tac Membrane fixed screw set Lingual bone tac holder Titanium screw
$2,400.00$2,200.00
Biotem
Each pack comes with: Abutment Male processing set 3 retention caps - Pink: 2.4 lbs, Blue: 1.2 lbs; Red: extra light angled, 0.8lbs Metal housing White spacer
$85.00
Non-Resorbable PTFE Membrane
Cytoflex Textured Tefguard is a non-resorbable PTFE membrane made of a proprietary micro-porous expanded polytetrafluoroethylene (ePTFE) material, that is ideal for socket preservations and bone grafting procedures. The textured version of Cytoflex Tefguard has superficial macro texture overlapping the micro pore texture on both surfaces, providing additional grips for flap attachment. Overlaying macro and micro textures on both surfaces! Allows nutrient permeation across the membrane. Resists fibroblasts and blocks bacterial penetration. Excellent Handling & Rigidity. Easily adaptable. Easily retrievable as one piece. Enhanced flap grips with fewer flap dehiscences Facilitates tissue regeneration despite flap recessions, or incomplete primary closure. Available in 12mmx24mm and 25mmx30mm. Provided double pouched and sterile. Cytoflex Textured Tefguard Benefits The textured version of Cytoflex® Tefguard® has superficial macro texture overlapping the micro pore texture on both surfaces. The cellular level micro texture is invisible to the naked eye, but can be seen at high magnifications. The macro texture provides additional grips for flap attachment. Allows nutrient permeation across the membrane for healthy bone regeneration. Resists fibroblasts and blocks bacterial penetration keeping the site safe from infection. Excellent Handling & Rigidity. Easily adaptable. Easily retrievable as one piece Better host tissue attachment with fewer flap dehiscences Easily retrievable as one piece Better host tissue attachment with fewer flap dehiscences Facilitates tissue regeneration despite flap recessions, or incomplete primary closure. Cytoflex ® Tefguard ® - Clinical Case Review MINIMALLY INVASIVE IMPLANT SITE GRAFTING TECHNIQUE Jenchun Chen DDS This is a 38 year-old female who presented with a crown-root fracture of the mandibular first molar and a thin gingival biotype. An immediate implant placement following tooth extraction was planned. A flapless, minimally invasive extraction and implant placement combined with guided tissue regeneration was employed to minimize soft and hard tissue recession. The tooth root was extracted with an intrasucular incision and a periosteal elevator. The extraction socket was curetted to remove all soft tissue remnants. After an implant was placed into the extraction site, the gap between the implant and the socket wall was filled with bone graft particles (Figures 1 & 2). A Tefguard® ePTFE membrane was trimmed to extend 3 mm beyond the socket walls and then tucked subperiosteally under the lingual flap, the buccal flap and underneath the interdental papilla using a curette. The membrane was allowed to rest passively over the socket (Figure 3), and was stabilized with a criss-cross absorbable PGA monofilament suture without primary closure (Figure 4). After one-week post operation, the graft site was uneventful, and the suture was removed (Figure 5). At three-week post-operation, the soft tissue overlying the exposed membrane demonstrated healing without signs of inflammation. An inadvertent fold in the membrane (introduced during membrane placement) was found at the distal buccal corner (Figure 6). The decision was made to remove the membrane early to prevent potential complications as a result of the folding of the membrane. After applying topical anesthetic, the membrane was easily removed by grasping with a tissue forcep. A dense, vascular connective tissue matrix was found underlying the membrane in the extraction socket upon membrane removal. Figure 7 shows the site at one week after membrane removal. Following membrane removal, keratinized gingiva began to form over the grafted socket. At six-week post-operation, the soft tissue was stable with preserved interproximal papillae and natural mucogingival architecture (Figure 8). This case demonstrates the use of a less invasive grafting technique using a micro porous ePTFE barrier.
$45.00 - $55.00
Automatic Bone Tac kit: TBM-05
Effectively secure membranes with the touch of a button with this Automatic Bone Tack kit. The unique handle drives titanium alloy tacks that stabilize the membrane. Kit includes: Automatic Tack handle with New Pull Back Mechanism Bone tack remover (BT-RM) Bone tack case with 21 tacs 21 Titanium Tacks (2.5mm D) - choose either 3.5mm short tacs or 4.5mm Long tacs. Additional tacs can be purchased separately here This Automatic Bone Tack holder is only compatible with MCT tacs Stabilize the membrane during the suturing process with the bone tac. Helps stabilize membranes from moving Reduce dental implant surgery time Screw type tac is recommended for Non-Resorbable membrane Tacs are made of titanium so they do not need to be removed Tacs can be purchased separately
$950.00
Piezo Surgical Tip Kit - Implant
Mectron Compatible Woodpecker US-II LED Compatible
$45.00 - $250.00
OsteoGen Plug, Large (10x20mm), 10/pk: Get $50 off promo
*Effective Feburary 1, 2026: Price will increase from $549 to $579 The OsteoGen ® Plug combines bone graft with a collagen plug to yield the easiest and most affordable way to clinically deliver bone graft for socket preservation and ridge maintenance without the use of a membrane. Eliminate hassle of mixing particulate grafts. Eliminate graft wash out. Radiolucent on day of surgery – Radiopaque in 3-6 months Sold in packs packs of 10. Available in Large: 10mm in Diameter x 20mm in Length OsteoGen® proven safe, and clinically effective for use with implants for over 30 years. The OsteoGen® Bone Grafting Plug is the easiest and most affordable way to clinically deliver bone graft for ridge maintenance and socket preservation. The idea is simple - we take a collagen plug and fill it with our OsteoGen® non-ceramic bone graft crystals to create the OsteoGen® Bone Grafting Plug. The result is a bone graft combined with a collagen plug for ease of clinical delivery – all at the introductory special price of only $50 per extraction without the need for a membrane. The OsteoGen® Bone Grafting Plug combines our OsteoGen® Bioactive Resorbable Calcium Apatite with a bovine achilles tendon collagen matrix to create a structure that mimics the organic and inorganic components of physiologic bone. OsteoGen® is a bioactive and resorbable calcium apatite based bone graft that is physicochemically and crystallographically similar to human bone.1 The OsteoGen® non-ceramic production process yields a resorbable bone graft with a unique Ca:P ratio that is NOT a ß-TCP and NOT a non-resorbable dense ceramic HA, nor is it a biphasic mixture of the two.
$579.00
ACE Surgical
Each pack comes with: Abutment Male processing set 3 retention caps - Pink: 2.4 lbs, Blue: 1.2 lbs; Red: extra light angled, 0.8lbs Metal housing White spacer
$85.00 - $110.00
Multi Unit Abutment Impression Coping (Transfer)
Multi Unit Abutment Impression Coping (Transfer), Closed Tray, Diameter: 4.8, Length: 5.5
$25.00
$75.00
Surgikor
Each pack comes with: Abutment Male processing set 3 retention caps - Pink: 2.4 lbs, Blue: 1.2 lbs; Red: extra light angled, 0.8lbs Metal housing White spacer
$85.00 - $110.00